Model | EVDC1-30K-C-EU |
---|---|
Input | |
Grid Connection | 3W+N+PE, 3W+PE |
Voltage Range | 400Vac ± 15% |
Rated Frequency | 50Hz |
Power Factor | ≥0.99 (Rated Load) |
Maximum Input Current | 60A |
Output | |
Rated Value | 1000V / 30A |
Rated Power | 30kW |
Voltage Range | 150Vdc – 1000Vdc |
Current Range | 0 – 100A |
System | |
Maximum Efficiency | >96% |
Charging Connector | CCS2 |
Cable Length | 5.5m |
RFID Reader | ISO 14443A / ISO 14443B |
Authorization Mode | Plug & Charge / RFID card / App |
Communication | Wi-Fi 2.4GHz/5GHz 802.11a/b/g/n, Bluetooth 5.2, 4G, FE 100Mbps, RS485, RS232 |
Display | 10.1″ high resolution touch screen, IK10 |
Protocol | OCPP 1.6i, OCPP2.0.X (optional) |
Safety | |
Ingress Protection Rating | IP65 |
Impact Protection | IK10 |
Protection | Over current protection, Ground protection, Surge protection, Over/Under voltage protection, Over/Under frequency protection, Over temperature protection, Relay Welding Detection, Residual current protection(optional) |
Certification | CE,UKCA |
Certification Standards | IEC 61851-1, IEC 61851-23 IEC 61000-1/3, IEC 61851-21 EN300 328, EN 301 489, EN 300 330, EN 62311 |
Warranty | 2 years |
Environment | |
Installation | Wall-mounted / Pedestal-mounting / Movable cart (Optional) |
Operating Temperature Range | -35°C – 50°C (>50°C derating) |
Relative Humidity | 5% – 95% RH |
Operating Altitude | <2000m |
Cooling | Forced Air Cooling |
Dimension (W×H×D) | 672×682×229mm |
Weight | ≈62kg |
Reviews